AMV4000F
Developed for production weld monitoring, it can store data from 255 passes including:- Process
- Average pass values
- Heat input
This data is available as a text file that can be easily imported into a database. Temperature can be stored as either an average of the dynamic value throughout the pass or as the starting, interpass temperature.
Previous pass data can also be used to create alarm levels that will automatically generate out-of-tolerance warnings.
Welding Waveform Analysis
The AMV 4000F can record the welding waveform. Hence it is possible to see the effects of changing parameters on the process. This can be invaluable for procedure development where understanding the mode of metal transfer can help improve productivity and reduce defects.Built-in algorithms determine pulse parameters.
| Channel | Parameter |
|---|---|
| 1 | Voltage |
| 2 | Current |
| 3 | Wire Feed Speed |
| 4 | Temperature |
| 5 | Gas Flow |
| 6 | - |
| 7 | - |
| 8 | - |